 Power Capacitor Thyristor Module TSM-LC
Preliminary data
Accessories B44066T0025E402 and B44066T0050E402
Characteristics Fast electronically controlled, self-observing thyristor switch Usage in dynamic (fast) power factor correction systems For capacitive loads up to 50 kvar
Features Easy installation Display and control via LED-display Permanent self-controlling
Technical Data
-
self-check after turn-on of main voltage operation faults activation voltage parameters phase sequence capacitor output
Dimensions Weight Voltage Frequency Max. power
157 x 200 x 180 mm (w x h x d) 4.8 kg 3 x 400 V 50 Hz / 60 Hz TSM-LC 25: 25 kvar for PFC-systems with/without reactors up to 14% TSM-LC 50: 50 kvar for PFC-systems with/without reactors up to 14% (cascading of several modules possible for increasing the kvar output) 10-24 VDC, internally insulated 2 LED / Phase connection: 2 x two-phase (L1, L3) with 4 terminals 25 qmm cross section Pv (W) = 2,0 x I (A) 25 kvar: at 400 V typical 75 W 50 kvar: at 400 V typical 150 W 3 x electronic fuse superflink" (NH00 AC 690V) 50 kvar: 125 A (e.g. SIBA Art.No.: 20 209 20-125) 25 kvar: 63 A (e.g. SIBA Art.No.: 20 477 20-63) approx. 5 ms -10 C ... +60 C TSM-LC 25: B44066T0025E402 TSM-LC 50: B44066T0050E402
Activation Display Power circuit Thermal power Fuses* (required for protection of TSM-LC and capacitor):
*not included in the content of delivery
Switching time Operating ambient temperature Ordering code
U Please read cautions on page 4 of this data sheet and information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case, bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications. Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to approve our product specifications or request our approval for your specification before ordering. FK PM PFC/PJ Page 1 of 4 July 2004
Power Capacitor Thyristor Module TSM-LC
Preliminary data Connection diagram
L1 (R) L2 (S) L3 (T) N PE Fuse superfast 125A at 50kvar 63A at 25 kvar
Accessories B44066T0025E402 and B44066T0050E402
Capacitor branch
input (controller signal)
_ + Signal 10-24VDC
L1 fault/ "O n" operation
L3 fault/ "O n" operation
TSM - LC
electronic thyristor-module for capacitor switching
C1
L1
L3
C3
Detuning reactors or BD100
EW-22 U Please read cautions on page 4 of this data sheet and information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case, bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications. Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to approve our product specifications or request our approval for your specification before ordering.
FK PM PFC/PJ Page 2 of 4
July 2004
Power Capacitor Thyristor Module TSM-LC
Preliminary data
Accessories for TSM-LC modules
Accessories B44066T0025E402 and B44066T0050E402
Discharge resistors EW-22 High voltage resistors type EW -22 required to discharge the capacitor. U Standard resistors must not be used! Technical Data Voltage Output Usage Dimensions Ordering code
1200 V 100 W For 25 kvar or 50 kvar step; one unit per step required 90 x 100 x 25 mm (w x h x d) B44066T0022E400
Current limitation reactor BD100 U Mandatory for usage of TSM-LC in PFC-systems without reactors. Technical Data Inductivity Rated current Linearity Usage Dimensions Ordering code
0,1 mH 85 A (50Hz) 120 A For PFC-systems without reactors; for 25 kvar or 50 kvar step; two units per step required 75 x 90 x 90 mm (w x h x d ) B44066T0100E400
U Please read cautions on page 4 of this data sheet and information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case, bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications. Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to approve our product specifications or request our approval for your specification before ordering.
FK PM PFC/PJ Page 3 of 4
July 2004
Power Capacitor Thyristor Module TSM-LC
Preliminary data Cautions:
Accessories B44066T0025E402 and B44066T0050E402
U
-
-
Live parts in the PFC equipment must not be touched! Warning signs in the PFC systems are required! Wait 10 minutes after the main switch is turned off - until the voltage in the system has dropped to an uncritical value. In non-detuned systems (400 V grid) capacitors with a higher voltage rating (e.g. 440 V) are needed. In detuned systems (400 V grid) capacitors with a voltage of 525 V are needed. For discharging the capacitors, special high-voltage resistors type EW22 are required. Standard resistors cannot be used! In dynamic PFC systems discharge reactors cannot be used! This would be a short circuit of the high-DC-voltage. In PFC systems without filter circuit reactors current limiting reactors are required (e. g. BD-100) for the TSM-LC. For short circuit protection, superfast electronic fuses for protection of the thyristor are required, standard HRC fuses are not suitable:
-
63 A / 690 V (25 kvar) - 3 pieces per module 125 A / 690 V (50 kvar) - 3 pieces per module
FAILURE TO FOLLOW CAUTIONS MAY RESULT, WORST CASE, IN PREMATURE FAILURES OR PHYSICAL INJURY.
U Please read cautions information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case, bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications. Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to approve our product specifications or request our approval for your specification before ordering.
EPCOS AG 2004. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed.
FK PM PFC/PJ Page 4 of 4
July 2004


▲Up To Search▲   

 
Price & Availability of B44066T0050E402

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X